D6 Labs SentIO_LogoD6 Labs Header-bknd-sentioPage 11-844-365-8647© Copyright 2026 Digital Six Laboratories, All Right ReservedD6 Labs Logo_D6-Labs_Whitewww.d6labs.comsales@d6labs.comSIO-EX-MC-SE-SIMMNNNN-xxModbus RTU—RS-485D6 Labs SentIO_ProdIntroductionThe Sent.io™ DIRECT2CLOUD I/O gateway is perfect for stand-alone IoT monitoring in a variety of applications including building management, oil and gas, water/wastewater and much more.Sent.io™ Modbus RTU can read and write modbus registers in any Modbus RTU compatible device including PLCs, HMIs, sensors, actuators, and more. Its read rules are configured from the cloud and can be setup to read and push up to thirty-two process values. Modbus read rules are executed continuously to support real-time alert notification when there are problems. Process variables are pushed to the cloud every 5 minutes.Sent.io™ Modbus RTU gives you an easy path to bring existing automation, SCADA, PLC or field I/O to the cloud so you customers and stakeholders can monitor and manage remotely using their mobile phone or PC.Sent.io™ communicates securely to the cloud using a built in 4G Cat M1 modem so it does not require access to customer networks or support from customer IT personnel. Our proprietary Cat M1-MC™ technology allows Sent.io™ to seemlessly switch between AT&T, T-Mobile, and Verizon, ensuring reliability without the need for separate SIM cards.Ordering InformationPart NumberDescriptionSIO-EX-MC-SE-SIMMNNNN-LRModbus RTU RS-485, Int AntSIO-EX-MC-SE-SIMMNNNN-XRModbus RTU RS-485, Ext AntFeaturesModbus RTU (RS-485)Thirty-two (32) read/write process variablesRead-rules configured in the cloud, automatically downloaded to deviceCatM1-MC - Works with Verizon, AT&T, & T-MobileDirect2Cloud air-gapped communicationsIP67 rated outdoor enclosure (DIN Rail, wall/pole mount)Simple to install, easy to use24/7 remote monitoring /control from anywhereConnector WiringThis Sent.io™ is configured with one (1) external channels:4231Con 2 (Left(opt))4231Con 1 (Right)ConnectorPinFunctionDescription11Vin8-32 VDC12Channel 2RS485-13Channel 3RS485+14GroundCircuit ground21Vin8-32 VDC22Channel 1Power Detection-active low23Not usedNot used24GroundCircuit ground
Page 21-844-365-8647© Copyright 2026 Digital Six Laboratories, All Right ReservedD6 Labs Logo_D6-Labs_Whitewww.d6labs.comsales@d6labs.comMechanical Drawing - Modbus RTU—RS-485D6 Labs Sent.io™2Smart™sensor interfaceMechanical Drawing* Dimensions are in inchesProduct AttributesTypeDescriptionOperating Temperature Range-40 - 185°FAnalog Input Current Range4-20 mAPower Supply (External DC Power Option)8-32 VDCPower Supply Current--Average50mA (typical)Power Supply Current--Peak21A (typical)1) Depends on installed sensors and operating environment2) Peak current at 3.6V