®Technical SpecificationsEx-DELTA®INSTRUMENTS, LLC.Product Data SheetPDS-VX2026-07-31Ex-DELTAVortex FlowmeterDescriptionRugged, yet simple, the Ex-DELTA vortex flowmeter is suitable for a variety of applications in liquid, gas, air and steam flows. Sparling/Oval vortex flowmeters are volumetric flow measuring devices constructed with stainless steel bodies which provide accurate and reliable measurement for years in industrial service.The various body styles provide complete flexibility of installation including wafer, flanged and replaceable sensor style which allows servicing of the snsor without shutting down the process flow.Principle of OperationSparling Vortex Meters measure flow rate based on Karman's vortex shedding principle. The stationary trapezoidal object (bluff body) placed into the path of the flow stream sheds vortices downstream at a frequency proportional to the velocity of flowing media. A piezoelectric sensor detects the vortices and creates electrical impulse signals which is proportional to the fluid flow rate.ApplicationsThe Ex-DELTA measures liquid gas, or steam flows in one flowmeter throughout your plant. Having a wide flow and temperature range, it can be extensively used in numerous applications.Common Applications Include:•measurement of steam, saturated steam in power plants, chemical plants, refineries and steel plants•Gas flow (nitrogen, oxygen, argon, etc) measurements and monitoring•demineralized and pure water in biotech, semiconductor and pharmaceutical•air flow measurement•oil and crude methanol up to 100cp•HVAC•food processing
®INSTRUMENTS, LLC.Features•Standard ±1% Accuracy•Sizes available from 0.5" - 6"•The unique casting design provides simple construction without any moving parts, ease of use and service in the field and long life. The net result is essential savings in initial cost, running expense and total cost.•SST trapezoidal body and embedded piezoelectric sensor avoids contact with process fluid.•Fixed and replaceable sensors. The replaceable sensor design allows servicing of the sensor without interrupting the flow and without taking the meter out from the pipeline. This is suitable for long term processes and avoids stocking of the replacement spool pieces.•High temp sensors to 788°F (420°C) Standard temperature range of -22°F - 572°F The wide range of temperature and pressure allows flow measurement of a variety of fluids.•NEMA 4X Enclosure•User selectable rate and total display - Integral mount transmitter with instantaneous flow rate indicator and totalizer•The EX DELTA is also available as battery powered (without 4-20mA). This will eliminate the need of an external power source and saves wiring and installation costs. The meter will display low battery indication when a new battery is required.•Explosion Proof (Optional)•Optional remote mount transmitter allows monitoring of the flow from a remote or central location.•Battery powered unit is also available on a remote mount transmitter.•EL2300 laptop interface allows the user to change flow meter range from a remote location.•4-20mA or Scaled Pulse OutputsSize (in)LIMeter I.D.Meter O.D.HWeight (lbs)0.5002.601.300.6001.6010.97.001.002.601.301.002.6010.98.001.503.101.601.503.2010.310.02.003.101.601.903.6010.510.03.003.901.602.905.0011.116.04.004.991.603.706.1011.924.06.006.501.905.508.503.1046.0
®INSTRUMENTS, LLC.Size (in)Flange RatingLIMeter I.D.HWeight (lbs)2.00ANSI 1508.004.001.9010.524.02.00ANSI 3008.504.301.9010.528.03.00ANSI 1509.304.002.9011.142.03.00ANSI 30010.04.602.9011.152.04.00ANSI 15010.84.803.7011.958.04.00ANSI 30011.65.203.7011.979.06.00ANSI 15013.45.605.5013.11056.00ANSI 30014.15.995.5013.11488.00*13.8*7.9013.788.010.0*17.7*9.8014.515412.0*19.7*11.715.4198Size (in)Flange RatingLIMeter I.D.HWeight (lbs)2.00ANSI 1508.004.001.9013.723.02.00ANSI 3008.504.301.9013.727.03.00ANSI 1509.304.002.9014.341.03.00ANSI 30010.04.602.9014.351.04.00ANSI 15010.84.803.7015.060.04.00ANSI 30011.65.203.7015.081.06.00ANSI 15013.45.605.5016.31046.00ANSI 30014.15.995.5016.31468.00*13.8*7.9016.987.010.0*17.7*9.8017.715312.0*19.7*11.718.6197
LiquidGasSize (in)Liquid (GPM)Min. FlowMax. Flow0.53.5226.4217.0588.11.510.6211.3213.21347.8320.25757.3448.431301.36145.328408211.3497510466.7770512664.811052Size (in)Gas (ACFM)Min. FlowMax. Flow0.56.7419.43112.3476.511.518.56170.67224.51288.37346.21647.35480.761088.73617424568300.83412010650.16618012928.88878Above table is based on typical liquid (water) measurement, sp. gravity 1 at 70°FAbove table is based on air measurement at 70°F & atmosphere pressure of 15 psiSteam*= Accuracy ±1% Full Scale()= Accuracy ±1.5% ReadingAccuracy=±1% Full Scale ReadingPressure (psi)0.5"1"1.5"2"3"4"6"8"10"12"7Min12*223148*6488176308660114425083608Max642465509242090(2618)3520(4488)7942(9812)13310(17204)19998(26620)28380(38060)14Min13*224455*64110198352748129828824114Max8132171712102706(3410)4576(5852)10340(12760)17336(22220)25960(34540)36960(49720)28.4Min13*224672132264462968169437625390Max81466104517603960(4950)6666(8514)15048(18560)25080(32560)37620(50380)53900(72160)57Min2459991763746161342233251487392Max191752168128386358(7986)10714(13706)24200(29700)40480(52360)60720(80960)86900(116160)71Min29661121984187041496261857868272Max227893199333667546(9482)12716(16280)28600(35420)47960(62040)72160(96140)103180(137940)100Min33811342204848361782312469089900Max2971170259644009900(12430)16676(21340)37620(46420)62920(81400)94600(126060)135080(180840)128Min37921542645505509463608796411396Max36714483212545612254(15356)12254(15356)20592(26180)77880(99000)116820(155980)166980(222200)157Min42103172286616107823104048895412826Max43817253828649014586(18260)24420(31240)55440(68420)992840(119900)139260(185680)198880(266200)171Min44110180308660112224424246941613483Max47318614136699615730(19756)26400(33880)59840(73700)100100(129360)150260(200420)214720(286000)199Min491191983307261232266248401012014762Max54121324752803018040(22440)30140(38720)68420(84480)114620(148060)172260(228800)244200(327800)228Min531302163527701320288250601117615994Max61223985368906420372(25520)34100(43780)77220(95480)129580(167200)183260(257400)277200(369600)257Min571392313968361430310254341201217292Max68268459841012022660(28380)38060(48840)86240(106480)144540(186560)216700(288200)308000(413600)284Min591502464189021518330057861280419052Max752294866001115424860(31240)42020(53900)95040(117260)159280(205700)237600(316800)341000(455400)426.3Min7719131952811441980426884701656628160Max1104433497021639036740(45980)61820(79200)139700(172480)233200(301400)349800(466400)501600(671000)568Min95233385638138623765170112422169237400Max146757641289922178048840(61160)82060(105160)185680(228800)310200(400400)466400(620400)666600(891000)612Min99244405660145224865412121002332040040Max15776204138602332052580(65780)88440(113080)199760(246400)334400(431200)501600(668800)717200(959200)
®INSTRUMENTS, LLC.How to order a Smart Ex-DELTATable 1: BaseModelNumberVXW - Wafer type body styleVXF - Flange type body styleVXR - Flanged replaceable sensorTable 2: Applications1 - StandardTable 3: Size015 - 0.5"025 - 1"040 - 1.5"050 - 2"080 - 3"100 - 4"150 - 6"200 - 8"250 - 10"300 - 12"Table 4: MeterBodyMaterialN - Stainless Steel Casting (0.5-6")C - 316 stainless steel or equivalent (8-10")Z - OtherTable 5: PressureRating5 - 150 psi6 - 300 psi9 - OtherTable 6: SensorConstruction1 - 1.5-12"2 - 0.5-1" (separate sensor type)Table 7: FluidsG - Gas (below 572°F)L - Liquid (below 572°F)S - Gas or Steam (to 788°F) - Replaceable sensor onlyH - Liquid (to 788°F) - Replaceable sensor onlyTable 8: PreampConstruction1 - Integral Mount2 - Remote MountTable 9: ExplosionProofConstruction0 - None1 - Explosion ProofTable 10: Display0 - None1 - Totalizer or Digital IndicatorTable 11: Output5 - Pulse Output6 - 4-20mA0 - Battery PoweredTable 12: OptionsHARTFieldbusModelAppsSizeMaterialPressureSensorFluidsPreamp.Exp. ProofDisplayOutputVXW1015N52G1005
®INSTRUMENTS, LLC.Standard SpecificationsAccuracy:±1% Full ScaleRepeatability:±2% of full scaleOutputs:4-20mA(0-100 Seconds) or scaled pulse, Unscaled Pulse-pulse levels: "0"-4mA, "1"-20mADisplay:User selectableSingle Line, 8 digit totalizer7 digit flow ratePercent full scale8 section bar graphPower Requirements:12-45VDC or Battery PoweredEnclosures:NEMA 4X Explosion Proof (Optional)End Connections:Wafer or FlangedFlow Ranges:See TablesProcess Fluids:Gas, Steam, Air, Super Heated Steam, Saturated Steam, Dirty Liquids (EX DELTA DIA)Construction Material:Meter Body: Series 300 SST or 316 SSTBluff Body: 316 SSTEnclosure: NEMA 4X Aluminum alloy with baked melamine finishPressure Rating:•Wafer style design pressure is rated up to 725 psi.•Check the connecting flange rating for flange style meters (150 psi, 300 psi)Operating Temp.:-22°F to 572°FHigh Temp. Construction:788°FApprovals:Cenelec, CSA, FM