D6 Labs SentIO_Logo
D6 Labs Header-bknd-sentio
Page 1
1-844-365-8647
© Copyright 2026 Digital Six Laboratories, All Right Reserved
D6 Labs Logo_D6-Labs_White
www.d6labs.com
sales@d6labs.com
SIO-EX-MC-SE-SI55NNNN-xx
2x 0-5V analog inputs
D6 Labs SentIO_Prod
Introduction
The Sent.io™ DIRECT2CLOUD I/O gateway is perfect for stand-alone IoT
monitoring in a variety of applications including building management, oil
and gas, water/wastewater and much more.
Sent.io™ has multiple power options to fit any application, including
internal battery, external 8-32V DC, and solar. The 0-5V variant is
configured with two 0-5V analog inputs via IP67 rated M8 connectors on
either side of the device. Sent.io™ has an internal 18V DC power supply
for sensors that it switches on during sample and off during sleep to
increase battery life. Analog inputs are measured every 5 minutes and
stored in non-volatile memory; every 4 hours, all buffered sensor
readings are pushed to the cloud. The cloud is notified immediately if an
input crosses a user-defined alert threshold, providing real-time
notification when problems occurs.
The Sent.io™ IoT gateway is perfect for monitoring applications including
tank level, flow rate, metering, water chemistry, temperature, pressure,
and much more.
Sent.io™ communicates securely to the cloud using a built in 4G Cat M1
modem so it does not require access to customer networks or support
from customer IT personnel. Our proprietary Cat M1-MC™ technology
allows Sent.io™ to seemlessly switch between AT&T, T-Mobile, and
Verizon, ensuring reliability without the need for separate SIM cards.
Ordering Information
Part Number
Description
SIO-EX-MC-SE-SI55NNNN-xx
Dual 0-5V analog in, Battery,
Int Ant
SIO-EX-MC-SE-SI55NNNN-XR
Dual 0-5V analog in, Ext Power,
Ext Ant
SIO-BA-MC-SE-SI55NNNN-LR
Dual 0-5V analog in, Battery,
Int Ant
SIO-BA-MC-SE-SI55NNNN-XR
Dual 0-5V analog in, Batteyr,
Ext Ant
Features
•
2x Analog Input 0-5V
•
18V Switched Sensor Power
•
Multiple Power Options—Battery, DC, MicroUPS
•
CatM1-MC - Works with Verizon, AT&T, & T-Mobile
•
Direct2Cloud air-gapped communications
•
IP67 rated outdoor enclosure (DIN Rail, wall/pole
mount)
•
Simple to install, easy to use
•
24/7 remote monitoring /control from anywhere
Connector Wiring
This Sent.io™ is configured with
two (2)
external channels:
4
2
3
1
Con 2 (Left(opt))
4
2
3
1
Con 1 (Right)
Connector
Pin
Function
Description
2
1
Vout
Sensor Supply Voltage
2
2
Channel 1
0-5 VDC Analog Input
2
3
Channel 2
0-5 VDC Analog Input
2
4
Ground
Circuit ground
1
1
Vin
8-32 VDC
1
2
Channel 1
Power Detection-active low
1
3
Not used
Not used
1
4
Ground
Circuit ground
Page 2
1-844-365-8647
© Copyright 2026 Digital Six Laboratories, All Right Reserved
D6 Labs Logo_D6-Labs_White
www.d6labs.com
sales@d6labs.com
Mechanical Drawing - 2x 0-5V analog inputs
D6 Labs Sent.io™2Smart™sensor interfaceMechanical Drawing
* Dimensions are in inches
Product Attributes
Type
Description
Operating Temperature Range
-40
-
85°C
Analog Input Current Range
0-5 VDC
Power Supply (External DC Power Option)
8-32 VDC
Power Supply Current--Average
50mA (typical)
Power Supply Current--Peak
2
1A (typical)
Battery Backup (MicroUPS Power Option)
1
48Hours (typical)
Battery Life
1
2-10 Years (typical 8 years)
Battery Backup (MicroUPS Power Option)
1
48Hours (typical)
1) Depends on installed sensors and operating environment
2) Peak current at 3.6V