Ultrasonic Tank Level Sensor,
91.4 Centímetro
Cable
D6 Labs Ultra-Sonic Drawing
Descripción general
Este sensor externo está diseñado para funcionar con un
Whisker.Block
®
configurado con una entrada analógica externa (A5)
de 0-5 VCC. When properly mounted, this sensor will detect tank
levels from
2.5 centímetros
to
8 metros
.
Poder
This sensor requires 3.3V for operation. The Whisker.Block
®
power
supply is 18V so a regulator to reduce the 18V supply down to 3.3V
is required.
Montura
This sensor is housed in a
5.1 centímetro
tube that is installed in the
top or lid of the tank facing downward with a clear view of the liquid
being measured. Mounting requires a
2.342 centímetro
hole
through which the device can be mounted. Take care not to
overtighten the nut.
Compatible Whisker.Blocks
®
Número de pieza
WB1-9-xx-A4A4A5A5-0000-xx
WB1-9-xx-A5NNNNNN-0000-xx
WB1-9-xx-A5NNNNNN-2001-xx
WB1-9-xx-A5A5NNNN-0000-xx
WB1-9-xx-DCA5NNNN-0000-xx
WB1-9-xx-DCA5A5NN-0000-xx
Wiring
D6 Labs Ultra-Sonic Diagram
Cableado recomendado:
Conector
Anclar
Cable del sensor
Descripción
1
1
Rojo
Fuente de alimentación del
sensor
1
2 or 3
Azul/Negro
Entrada analógica de 0-5 V
CC
1
4
White
Referencia de tierra